Categories
BLOG

elphaba’s bliss strain

Please verify you are a human

Access to this page has been denied because we believe you are using automation tools to browse the website.

This may happen as a result of the following:

  • Javascript is disabled or blocked by an extension (ad blockers for example)
  • Your browser does not support cookies

Please make sure that Javascript and cookies are enabled on your browser and that you are not blocking them from loading.

Reference ID: #1d177000-685b-11eb-a2cb-eb0f8e87bfe7

Please verify you are a human Access to this page has been denied because we believe you are using automation tools to browse the website. This may happen as a result of the following:

ORELAP Cert No. 4092-002
OLCC No. 1002158CD2E

Marijuana Potency Analysis by
High Performance Liquid Chromatography

Client Name, Sample Details

Terrapin Investment III
Grand Rapids, MI 49505
Sample: Elphaba’s Bliss
Type: Usable Marijuana
Method: FE04-OR4 HPLC1100-OR1
Metrc Test Pkg#: 1A4010300014565000001164
Metrc Source Pkg#: 1A4010300014565000001134
***Water Activity: 0.463
***Moisture: 11.01%

Test Conditions

Prepsheet ID#: P180717a
Scale: XS205-OR1
Temp: 21.3 °C
Baro Pressure: 1004 hPa
Analyst: HRM
Technician: EDT

Sample ID#: 109437

Lot #: O5
Batch #: 109437
Batch Weight (g): 3821
Harvest/Process Date: 06/25/2018
Package Weight (g):20.5
Date Received: 07/13/2018
Test Date: 07/17/2018

LOQ = Limit of Quantitation

RPD is relative percent difference between the LCS and LCS duplicate.

%RPD = Relative Percent Difference; Min. Value = Minimum Detectable Amount, CFU = Colony Forming Units, N/D = Not Detected

*** Designated tests that use the method FE-45.

Total CBD or THC is the calculated sum of CBD or THC and the amount of CBD or THC derived from CBDA or THCA, respectively. These values are calculated by adding a molar correction factor of 0.877 to the CBDA or THCA value.

SOP FE-01-OR9 was used in accordance with OAR 333-007 for sampling. All marijuana items are sampled and tested in accordance with OAR 333-007-0300 to 333-007-490 and OAR 333-064-0100 to 333-064-0110.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

Iron Labs Oregon complies with 2009 TNI Environmental Laboratory Standards.

Tested by Iron Laboratories Oregon, 71 Centennial Loop Suite D Eugene, OR 97401

ORELAP Cert No. 4092-002
OLCC No. 1002158CD2E

QC Report

Client Name, Sample Details

Terrapin Investment III
Grand Rapids, MI 49505
Sample: Elphaba’s Bliss
Type: Usable Marijuana
Method: FE04-OR4 HPLC1100-OR1
Metrc Test Pkg#: 1A4010300014565000001164
Metrc Source Pkg#: 1A4010300014565000001134
***Water Activity: 0.463
***Moisture: 11.01%

Test Conditions

Prepsheet ID#: P180717a
Scale: XS205-OR1
Temp: 21.3 °C
Baro Pressure: 1004 hPa
Analyst: HRM
Technician: EDT

Sample ID#: 109437

Lot #: O5
Batch #: 109437
Batch Weight (g): 3821
Harvest/Process Date: 06/25/2018
Package Weight (g):20.5
Date Received: 07/13/2018
Test Date: 07/17/2018

LR = indicates compound recovery of matrix spike was outside the methods acceptable limits. (70-130%) Low recovery should be scrutinized for possible fail as it could indicate more compound present than is detected.

I = indicates that an amount of an interfering compound greater than the methods limit of detection was detected in the method blank sample. May indicate contamination of analytical system or consumables.

Q = indicates that the relative percent diference of two identicly prepared Matrix Spike samples for a target analyte was greater than 20%

HR = indicates compound recovery of matrix spike was outside the methods acceptable limits. (70-130%) high recoveries should be scrutinized for passing as more compound may be detected than is actually present in the sample.

SOP FE-01-OR9 was used in accordance with OAR 333-007 for sampling. All marijuana items are sampled and tested in accordance with OAR 333-007-0300 to 333-007-490 and OAR 333-064-0100 to 333-064-0110.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

Iron Labs Oregon complies with 2009 TNI Environmental Laboratory Standards.

Tested by Iron Laboratories Oregon, 71 Centennial Loop Suite D Eugene, OR 97401

ORELAP Cert No. 4092-002
OLCC No. 1002158CD2E

Pesticide Analysis by
Mass Spectrometer

Client Name, Sample Details

Terrapin Investment III
Grand Rapids, MI 49505
Sample: Elphaba’s Bliss
Type: Usable Marijuana
Method: FE-52 (EN 15662 & AOAC 2007.01)
Metrc Test Pkg#: 1A4010300014565000001164
Metrc Source Pkg#: 1A4010300014565000001134

Test Conditions

Prepsheet ID#: PS180719a
Scale: Veritas-OR1
Temp: 21.0 °C
Baro PE: 1006 hPa
Analyst: JER
Technician: JER

Sample ID#: 109437

Lot #: O5
Batch #: 109437
Batch Weight (g): 3821
Harvest/Process Date: 06/25/2018
Package Weight (g):20.5
Date Received: 07/13/2018
Test Date: 07/20/2018

This sample has not been tested according to OAR 333-007. These results should therefore be used for research and development or quality control purposes only.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

Tested by Iron Laboratories Oregon, 71 Centennial Loop Suite D Eugene, OR 97401

ORELAP Cert No. 4092-002 OLCC No. 1002158CD2E Marijuana Potency Analysis by High Performance Liquid Chromatography Client Name, Sample Details Terrapin Investment III Grand Rapids, MI